To fix this problem of the flame sensor not allowing the furnace to light we must clean the flame sensor.
Clean furnace temperature sensor.
Then to clean the blower assembly remove the front panel clean the.
Before searching for the flame sensor for removal and cleaning we recommend you turn off the power to the furnace.
Ami parts furnace flame sensor for goodman 0130f00010 fit b1172606 b11726 06 20488501 acs90453bxa p1257001f p1257007f acs90703bxa p1257002f p1257008f replacement 4 5 out of 5 stars 73 4 39 4.
Remove it by pulling it down out of its bracket.
Check the flame sensor if present.
Http amzn to 2xcwdbv york luxaire tempstar.
The flame sensor occasionally becomes coated with residue and will prevent your furnace from lighting.
If you re willing to risk 120 and buy all three parts ahead of time you may be able to fix your own furnace in less than an hour and save a 125 service call.
Lightly clean the surface with fine emery cloth and slip the sensor back into its bracket.
Your readings should be 1 5 to 4 ua some manufacturer s control systems only need 0 5 ua so check the manual for the system you re testing.
If cleaning your flame sensor did not work it s possible that the sensor is broken and that the furnace is operating as it should.
In some furnaces this is easily done while with other gas furnaces the flame sensor is difficult to remove for cleaning.
If the filter is dirty replace it or clean it with soap and water if it s not disposable.
Hook up your multimeter in series with the flame sensor and the sensor wire and fire the furnace in a heat cycle.
You may need to replace the sensor in which case you can follow these same instructions with the exception that no sanding is involved.
Just remove one sensor and replace it with a new sensor.
Common replacement flame sensors.